Showing 1 - 10 of 15
A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m2 solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on...
Persistent link: https://www.econbiz.de/10008916991
In this study, a small scale hybrid solar heating, chilling and power generation system, including parabolic trough solar collector with cavity receiver, a helical screw expander and silica gel-water adsorption chiller, etc., was proposed and extensively investigated. The system has the merits...
Persistent link: https://www.econbiz.de/10008913643
A novel operation strategy based on minimum distance was proposed. Also, an integrated evaluation criterion which can reflect the matching performance between the CCHP (combined cooling, heating and power) system and the building was presented. A hospital in Shanghai was used to evaluate the...
Persistent link: https://www.econbiz.de/10010784909
A solar adsorption cooling system which can be switched between a system with heat storage and a system without heat storage was designed. In the system with heat storage, a heat storage water tank was employed as the link between the solar collector circulation and the hot water circulation for...
Persistent link: https://www.econbiz.de/10008919057
Solar powered solid desiccant cooling system is a good alternative to conventional vapor compression system. In this paper, a novel solar driven desiccant coated heat exchanger cooling (SDCC) system is proposed. In order to validate the feasibility of such system and to predict system...
Persistent link: https://www.econbiz.de/10010572017
Air conditioning system based on liquid desiccant has been recognized as an efficient independent air humidity control HVAC system. To improve thermal coefficient of performance, a novel two-stage liquid desiccant dehumidification system assisted by calcium chloride (CaCl2) solution is developed...
Persistent link: https://www.econbiz.de/10008916949
A novel chiller with open-cycle rotary desiccant cooling has been investigated experimentally. The technologies of two-stage dehumidification and regenerative evaporative cooling have been integrated together in this chiller. The objective of this study is to extend the ability for handling...
Persistent link: https://www.econbiz.de/10011040836
As a kind of distributed energy system, internal-combustion-engine-based cogeneration system is attracting increasing attentions for its environmental friendly and economic qualities. Some problems are encountered in the application, such as jacket water temperature control and the...
Persistent link: https://www.econbiz.de/10008918666
In order to optimize design and operation strategy of air-source heat pump water heater, an experimental set-up and simulation model were constructed. Also, a methodology of optimizing operation, which takes into account thermostatic and timing control patterns, was presented and applied....
Persistent link: https://www.econbiz.de/10011041270
A novel micro CCHP system, which is based on a two bed silica gel-water adsorption chiller, is constructed in this work. To reveal the chiller characteristic in this system, a transient model of the adsorption chiller is developed. According to the comparison of the simulated results and...
Persistent link: https://www.econbiz.de/10008916265