Showing 1 - 2 of 2
To improve heat transfer performance and reduce erosion of economizers in coal-fired power plants, firstly the heat transfer and erosion characteristics is numerically studied for the single H-type finned oval tube with enhanced heat transfer structures including bleeding dimples, longitudinal...
Persistent link: https://www.econbiz.de/10010776605
The experimental system for the transcritical CO2 residential air-conditioning with an internal heat exchanger was built. The effects of working conditions on system performance were experimentally studied. Based on the experimental dada, the second law analysis on the transcritical CO2 system...