Showing 1 - 9 of 9
, especially for space heating and cooling, are closely linked to several weather variables, mainly air temperature. The analysis … temperature. Base temperature should be chosen to coincide with the minimum energy consumption. In this way, changes in heating … and cooling requirements between the reference and the future period are calculated and areas about to undergo large …
Persistent link: https://www.econbiz.de/10011030939
Increasingly strict energy policies, rising energy prices, and a desire for a positive corporate image currently serve as incentives for multinational corporations to reduce their plants’ energy consumption. This paper quantitatively investigates and discusses the value of a traditional...
Persistent link: https://www.econbiz.de/10010675979
The best Weibull distribution methods for the assessment of wind energy potential at different altitudes in desired locations are statistically diagnosed in this study. Seven different methods, namely graphical method (GM), method of moments (MOM), standard deviation method (STDM), maximum...
Persistent link: https://www.econbiz.de/10011030733
. Calculations included pig number, slurry (manure water mixture) dilution, retention time and biogas/solar heating. Although using …:9 slurry dilution rate commonly used on pig farms. However, at a 1:3 slurry dilution, the use of solar heating to provide 90 …
Persistent link: https://www.econbiz.de/10011031163
The reduction of electricity use for heating and domestic hot water in cold climates can be achieved by: (1) reducing … the heating loads through the improvement of the thermal performance of house envelopes, and (2) using solar energy … a reference house for the study of long-term thermal storage. Third, the computer simulation of a solar heating system …
Persistent link: https://www.econbiz.de/10010676130
Earth-air heat exchange (EAHE) systems offer the possibility of reducing use of nonrenewable energy for heating … cold climates is small. Even less has been reported on their heating performance, but the available information suggests … heating with EAHE were found for cool climates. Four articles that addressed ground temperature effects with horizontal ground …
Persistent link: https://www.econbiz.de/10010681055
Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on …
Persistent link: https://www.econbiz.de/10011030904
the system performance identifying the specific cooling power (<i>SCP</i>) and coefficient of performance (<i>COP</i>). A …
Persistent link: https://www.econbiz.de/10011031298
ceiling insulation on the cooling load of gable-roof residential buildings are investigated based on the simulation of … ceiling insulation. Furthermore, it is predicted that the ceiling insulation plays a control role on the attic cooling load … and that an increase of roof pitch from 3/12 to 8/12 results in a decrease in the cooling load by around 9% in the …
Persistent link: https://www.econbiz.de/10010676134