Showing 1 - 10 of 25
Total thermal resistance of ground heat exchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the...
Persistent link: https://www.econbiz.de/10010805098
This paper presents a numerical heat transfer model for vertical U-tube Ground Heat Exchangers (GHE). This model is uniquely able to take into to account different initial soil temperatures and physical properties at different depths. The model has been validated based on an experimental case...
Persistent link: https://www.econbiz.de/10011045744
This paper presents a new hybrid two-dimensional model to simulate single U-tube ground heat exchangers based on the use of the electrical analogy to model heat transfer within the borehole and thermal response factors (short and long time-step g-functions) to estimate heat flow to the...
Persistent link: https://www.econbiz.de/10011208712
This paper develops previous research on passive house (PH) space heating. A simple and accurate ground heat exchanger model is developed. It is based on a numerical transient bi-dimensional approach that allows to computing the ground temperature at the surface and at various depths. The new...
Persistent link: https://www.econbiz.de/10010806356
This paper develops previous research on space heating in passive houses (PH). The results reported are based on a complex theoretical model used to simulate the heating system operation in Pirmasens PH (Rhineland Palatinate, Germany). The economic feasibility of different active space heating...
Persistent link: https://www.econbiz.de/10010806387
A novel approach is presented that allows to predict fluid temperatures entering a Ground Heat Exchanger (GHE) for parallel, series and mixed arrangements of boreholes. The method determines at each time step the heat transfer rates occurring at each borehole so as to reproduce the fluid...
Persistent link: https://www.econbiz.de/10010806719
Computer simulation of borehole ground heat exchangers used in geothermal heat pump systems was conducted using three-dimensional implicit finite difference method with rectangular coordinate system. Each borehole was approximated by a square column circumscribed by the borehole radius. Borehole...
Persistent link: https://www.econbiz.de/10010803683
Hourly energy simulations are an important part of the design and analysis of ground-source heat pump systems. In order to evaluate the fluid temperature in the borehole of a geothermal heat pump system, most of the current models express the heat transfer rate as a sum of step changes in heat...
Persistent link: https://www.econbiz.de/10010804062
An improvement to the thermal resistance capacity model (TRCM) used to model borehole heat exchangers is presented. Here, the original model is extended to integrate the thermal capacities of the heat carrier fluid and pipe and to better account for the spacing between the pipes. Model results...
Persistent link: https://www.econbiz.de/10010804076
The effective thermal conductivity of six vertical closed-loop ground heat exchangers (GHEXs), which were installed in a test bed located in Wonju, South Korea, has been experimentally evaluated by performing in-situ thermal response tests (TRTs). To compare the thermal efficiency of the GHEXs...
Persistent link: https://www.econbiz.de/10010804271