Showing 1 - 2 of 2
This paper makes a comparative analysis between a helical-shaped pipe and a double U-tube ground heat exchanger. The two configurations were installed at a shallow depth and studied, since a depth limit is mandatory in some areas. When installed this way, the interaction between the ground...
Persistent link: https://www.econbiz.de/10010702568
In this paper a numerical model to analyze the thermal behaviour of vertical ground heat exchangers with a helical shaped pipe is presented. This type of configuration can be a suitable alternative to conventional ground heat exchangers, especially when the heating and cooling loads of the...
Persistent link: https://www.econbiz.de/10010603035