Showing 1 - 10 of 16
Current alarm systems on intensive care units create a very high rate of false positive alarms because most of them simply compare the physiological measurements to fixed thresholds. An improvement can be expected when the actual measurements are replaced by smoothed estimates of the underlying...
Persistent link: https://www.econbiz.de/10009216959
This paper presents variance extraction procedures for univariate time series. The volatility of a times series is monitored allowing for non-linearities, jumps and outliers in the level. The volatility is measured using the height of triangles formed by consecutive observations of the time...
Persistent link: https://www.econbiz.de/10009219848
In intensive care, time series of vital parameters have to be analysed online, i.e. without any time delay, since there may be serious consequences for the patient otherwise. Such time series show trends, slope changes and sudden level shifts, and they are overlaid by strong noise and many...
Persistent link: https://www.econbiz.de/10009219880
In intensive care, time series of vital parameters have to be analysed online, i.e. without any time delay, since there may be serious consequences for the patient otherwise. Such time series show trends, slope changes and sudden level shifts, and they are overlaid by strong noise and many...
Persistent link: https://www.econbiz.de/10010296637
Current alarm systems on intensive care units create a very high rate of false positive alarms because most of them simply compare the physiological measurements to fixed thresholds. An improvement can be expected when the actual measurements are replaced by smoothed estimates of the underlying...
Persistent link: https://www.econbiz.de/10010296737
This paper presents variance extraction procedures for univariate time series. The volatility of a times series is monitored allowing for non-linearities, jumps and outliers in the level. The volatility is measured using the height of triangles formed by consecutive observations of the time...
Persistent link: https://www.econbiz.de/10010298200
Current alarm systems on intensive care units create a very high rate of false positive alarms because most of them simply compare the physiological measurements to fixed thresholds. An improvement can be expected when the actual measurements are replaced by smoothed estimates of the underlying...
Persistent link: https://www.econbiz.de/10003354944
This paper presents variance extraction procedures for univariate time series. The volatility of a times series is monitored allowing for non-linearities, jumps and outliers in the level. The volatility is measured using the height of triangles formed by consecutive observations of the time...
Persistent link: https://www.econbiz.de/10003483698
Persistent link: https://www.econbiz.de/10003977730
Persistent link: https://www.econbiz.de/10003623661