Showing 1 - 10 of 9,651
queueing systems in the literature. The total expected cost function per unit time is developed to obtain the optimal operating … (0,Q, N,M) policy at minimum cost. Copyright Springer-Verlag Berlin Heidelberg 2002 …
Persistent link: https://www.econbiz.de/10010999554
queueing systems in the literature. The total expected cost function per unit time is developed to obtain the optimal operating … (0,Q, N,M) policy at minimum cost. Copyright Springer-Verlag Berlin Heidelberg 2002 …
Persistent link: https://www.econbiz.de/10010847506
are obtained. A total expected cost function per unit time is developed to determine the optimal operating N-policy at … minimum cost. Copyright Springer-Verlag Berlin Heidelberg 2003 …
Persistent link: https://www.econbiz.de/10010999930
expected waiting time in the system are obtained. A total expected cost function per unit time is developed to determine the … optimal operating N-policy at minimum cost. Copyright Springer-Verlag Berlin Heidelberg 2003 …
Persistent link: https://www.econbiz.de/10010759525
Persistent link: https://www.econbiz.de/10010508003
equal to the traffic intensity. Cost model is developed to determine the optimal operating N policy at minimum cost …
Persistent link: https://www.econbiz.de/10010847859
equal to the traffic intensity. Cost model is developed to determine the optimal operating N policy at minimum cost …
Persistent link: https://www.econbiz.de/10010999865
, breakdown times, and repair times have exponential distributions. A cost model is developed to determine the optimal values of … the number of unloaders and the finishing rate simultaneously, in order to minimize the expected cost per unit time … numerical values given to the system parameters and the cost elements. Sensitivity analysis is also studied. …
Persistent link: https://www.econbiz.de/10005050668
document to these regulations, EPA published a Cost-Effectiveness (CE) Analysis (EPA, 1991). This report calculated the CE of … treatment option has a different cost and will result in removal of different levels of pollutants. The report calculates the … annualized cost for each option and the pound equivalents (PE) removed and expresses the CE as $/PE. While not officially …
Persistent link: https://www.econbiz.de/10009436420
Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are …), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions … for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility …
Persistent link: https://www.econbiz.de/10009437327