Showing 1 - 10 of 2,615
Fault-tolerable capability of Doubly Fed Induction Generator (DFIG) against disturbance occurrence is recognized as Fault Ride-Through (FRT). With quick and accurate compensation potentiality of Dynamic Voltage Restorer (DVR) to retrieve the nominal PCC voltage, DFIG can safely follow its normal...
Persistent link: https://www.econbiz.de/10011937731
Fault-tolerable capability of Doubly Fed Induction Generator (DFIG) against disturbance occurrence is recognized as Fault Ride-Through (FRT). With quick and accurate compensation potentiality of Dynamic Voltage Restorer (DVR) to retrieve the nominal PCC voltage, DFIG can safely follow its normal...
Persistent link: https://www.econbiz.de/10011864119
This paper is interested in the control of a wind energy conversion system (WECS) based on the doubly fed induction generator (DFIG) under grid fault conditions. A single line to ground fault and a double line to ground fault are tested during the hyper-synchronous operation of the DFIG wind...
Persistent link: https://www.econbiz.de/10010807485
Undoubtedly, energy has a significant role in economic growth and technical developments. Renewable energy resources are becoming more important in recent years due to their tremendous contributions to the independence of power generation industry from traditional fossil energy resources. Wind...
Persistent link: https://www.econbiz.de/10011049454
Wind Energy Conversion System (WECS) based on Doubly Fed Induction Generator (DFIG) connected to the grid is subjected to high transient currents at rotor side and rise in DC-link voltage during voltage sag at stator/grid side. To secure power system operation wind turbines have to meet grid...
Persistent link: https://www.econbiz.de/10011263811
In conventional generation systems, the possibility of system restoration and reducing power swings among different generation units is high, as an adequate reserve can be supplied from neighboring generation units to restore the operation. In contrast, the situation is different in the case of...
Persistent link: https://www.econbiz.de/10011264029
This paper presents a new direct power control (DPC) strategy for a double fed induction generator (DFIG) based wind energy generation system. Switching vectors for rotor side converter were selected from the optimal switching table using the estimated stator flux position and the errors of the...
Persistent link: https://www.econbiz.de/10010805612
In this paper, a network power flux control of a variable speed wind generator is investigated. The wind generator system consists of a doubly fed induction generator (DFIG) connected to the network associated to a flywheel energy storage system (FESS). The dynamic behaviour of a wind generator,...
Persistent link: https://www.econbiz.de/10010806474
This paper describes a doubly fed induction generator (DFIG) control for wind energy generation. The DFIG model is established and the adopted control strategies for machine side and grid side converters are described. Flicker phenomenon is defined and its emission of variable speed wind turbine...
Persistent link: https://www.econbiz.de/10010749975
This paper presents a new control strategy for a small scale wind farm which is composed of both fixed and variable speed wind turbine generator systems. Fixed speed wind generators (FSWGs) are largely dependent on reactive power, so they require large reactive power when a short circuit fault...
Persistent link: https://www.econbiz.de/10010804011