Showing 1 - 10 of 11
Persistent link: https://www.econbiz.de/10001494425
A novel dual hot gas bypass defrosting (DHBD) method is developed to remove frost from the outside heat exchanger (HEX) of an air-to-air heat pump. The proposed method adopts two bypass lines of hot gas from the compressor: one is connected to the inlet of the outdoor HEX, and the other is...
Persistent link: https://www.econbiz.de/10010572034
ASFs (Annular stepped fins) require less material than ADFs (annular disc fins) while retaining the ability to produce the same cooling rate in a convection environment. A simple analysis was developed for ASFs that considered radiative heat transfer and heat generated by a nuclear reactor...
Persistent link: https://www.econbiz.de/10010939830
We report a novel defrosting control method for refrigeration systems including refrigerators and heat pumps that commonly use time control or time–temperature control to determine the defrosting start-time. However, these methods do not provide accurate defrosting start-times due to...
Persistent link: https://www.econbiz.de/10011263265
This study presents a simple approach to estimate the capacity of combined heat and power (CHP) units suitable for installation in high heat-to-power ratio (HPR) buildings when excess electricity cannot be sold back to the grid. The two different methods used in this approach, a graphical method...
Persistent link: https://www.econbiz.de/10010807806
Like dry surface fins, development of the boundary layer over a wet fin causes the heat transfer coefficient to vary over the fin surface. The present study analytically determines the performance of different fins geometries by analyzing the temperature-dependent thermal conductivity of the fin...
Persistent link: https://www.econbiz.de/10010809490
We report a LDC (load duration curve) method to determine the optimum size of CHP (combined heat and power) units. The method gives the appropriate capacity graphically from the LDC of a building's heating demand. The method can be applied to the most common CHP units that are connected to the...
Persistent link: https://www.econbiz.de/10010810015
A solely analytical method is investigated to determine the minimum fin shape of wet fins subject to variable heat transfer coefficients. The analysis is applicable to any surface condition, including dry, fully wet and partially wet. An optimization procedure based on the variational principle...
Persistent link: https://www.econbiz.de/10010810452
Light-emitting diode (LED) lighting offers greater energy efficiency than conventional lighting. However, if the heat from the LEDs is not properly dissipated, the lifespan and luminous efficiency are diminished. In the present study, a heat sink of LED lighting was optimized with respect to its...
Persistent link: https://www.econbiz.de/10010737691
The size of a cooling inventory is generally designed based on which size can endure the excessive heat load situations that occur sporadically. As a result, cooling systems are often too large for most normal driving modes. There have been numerous efforts to downsize the automotive engine...
Persistent link: https://www.econbiz.de/10011053628