needed during design: both the borehole and the surrounding ground are affected by thermal exchange. The model here presented …-tube or coaxial pipes. Besides, ground temperature at different distances from borehole are calculated, taking into account …
Persistent link: https://www.econbiz.de/10010806238
A numerical model has been developed to study the complex thermal behavior of a CO2-filled vertical geothermal borehole …-state conservation equations of mass, momentum and energy is applied. The borehole is divided into small volume elements due to … relatively significant changes in the thermophysical properties of the fluid. Borehole wall temperature variations as well as …
Persistent link: https://www.econbiz.de/10010729381
Water pumping has been one of the main applications for wind power in the past and despite the spread of mains-electric pumps, more than a million windpumps remain in regular use. This paper reviews the general technical and economic requirements for pumping water using wind energy and by way of...
Persistent link: https://www.econbiz.de/10010803875
simulation of energy flows and temperature changes in and around a borehole heat exchanger when a fluid circulates through a U … obtained from experiments with real borehole set-ups in Cyprus. Then the validated model is used to study the heat flow and the …, the variation of the ground thermal conductivity and specific heat and the borehole filling material affect the …
Persistent link: https://www.econbiz.de/10010576250
. First, a one-dimensional radial numerical heat transfer model is developed to evaluate heat transfer from the borehole wall … using temperature measurements. The apparatus mimics the behavior of a geothermal borehole and uses a homogeneous saturated …
Persistent link: https://www.econbiz.de/10010702560
of safe and consistent water supplies for drinking and other domestic or agricultural uses. Borehole supplies are capable …
Persistent link: https://www.econbiz.de/10011044908
Analysis of borehole thermal resistance is important for the standard sizing of ground heat exchanger (GHE). In this … paper, a p-linear dimensionless average fluid temperature is proposed to estimate borehole thermal resistance. A p …
Persistent link: https://www.econbiz.de/10011045805
properties. A ground loop consisted of a rectangular field of 15 borehole heat exchangers is utilized to cover building loads …. GLD 2009 sizing software calculates borehole length setting two different fixed temperatures for the heat carrier fluid …
Persistent link: https://www.econbiz.de/10011040343
Energy piles have recently emerged as a viable alternative to borehole heat exchangers, but their energy efficiency has …
Persistent link: https://www.econbiz.de/10011209492
and borehole thermal resistance as parameters. An in-situ thermal response test provides a method to estimate these two … for the late-time period of the in-situ test. With this model one can estimate the soil thermal conductivity and borehole … length of the borehole. The analysis also indicates a p-linear averaging method gives smaller errors than the mean …