Showing 41 - 50 of 122
Persistent link: https://www.econbiz.de/10014576907
The results of numerical simulations of particle sticking behavior near the throat of a low-NOx axial-swirl burner in a 600-MWe bituminous coal burned boiler are presented. A comparison of simulation results with measurements using a probe with hot-film sensors shows that the numerical model...
Persistent link: https://www.econbiz.de/10008913728
Industrial experiments were performed for a retrofitted 660 MWe full-scale down-fired boiler. Measurements of ignition of the primary air/fuel mixture flow, the gas temperature distribution of the furnace and the gas components in the furnace were conducted at loads of 660, 550 and...
Persistent link: https://www.econbiz.de/10008918747
Within a gas/particle two-phase testing facility, multi-level concentrators were investigated by obtaining gas/particle two-phase characteristics of each concentrator within a centrally fuel-rich swirl burner. Measurements of velocities, particle volume flux profiles and relative particle number...
Persistent link: https://www.econbiz.de/10010808384
Due to the limits of reserves and price for the high rank coal, the low rank coal has been employed as fuel for power generation in China and will be eventually employed in the world. To burn low rank coal, centrally fuel-rich swirl coal combustion burner has been studied in Harbin Institute of...
Persistent link: https://www.econbiz.de/10010808985
By using phase-Doppler anemometry (PDA) measurements within a cold small-scale model for a down-fired 600-MWe supercritical utility boiler, gas/particle flow characteristics were acquired at various staged-air declination angle settings (i.e., 0°, 15°, 30°, and 45°) so as to assess the...
Persistent link: https://www.econbiz.de/10011053524
Industrial experiments were performed for a retrofitted 660-MWe full-scale arch-fired boiler. The ignition position of the primary air/fuel mixture flow, furnace temperature and flue gas component after the air heater were measured with different anthracite ratios at loads of 660- and 380-MWe....
Persistent link: https://www.econbiz.de/10010572077
A new overfire air (OFA) technology was proposed by the authors for a Foster Wheeler down-fired boiler, and a small-scale cold experimental system for a 660-MWe unit was established. The velocity field distribution was measured in the furnace to study the characteristics of single-phase flow in...
Persistent link: https://www.econbiz.de/10011054243
To investigate the aerodynamic field, cold airflow experiments were conducted under different boiler loads in a cold small-scale model of a down-fired pulverized-coal 300 MWe utility boiler. At 300 MWe and 250 MWe loads, a deflected flow field appeared in the lower furnace. In contrast, at a...
Persistent link: https://www.econbiz.de/10011054262
Air-surrounding-fuel is a well-known concept used within tangential and wall-fired boilers. Here, we report for the first time on industrial experiments performed to study the effects of this concept on a 660 MWe full-scale down-fired boiler. Data are reported for the gas temperature...
Persistent link: https://www.econbiz.de/10011054703