two-part series, reports on a modeling analysis where a semi-empirical model of the airside defrosting in the four …
Persistent link: https://www.econbiz.de/10010576276
Energy conserving is an important issue in greenhouse farming. Because greenhouse operations consume large amount of fossil fuel energy, energy conservation is necessary for securing famers’ income and alleviating global warming. Surplus air thermal energy (SATE) in greenhouses exists even in...
Persistent link: https://www.econbiz.de/10010635994
is capable of properly addressing single-phase connections, adequately modeling the unbalanced nature of LV networks …
Persistent link: https://www.econbiz.de/10010776604
provided. In the second part of the series, a modeling analysis on the effects of downwards flowing of the melted frost along …
Persistent link: https://www.econbiz.de/10010576312
When an air source heat pump (ASHP) operates in heating mode, frost can be accumulated on the surface of its finned outdoor coil. Frosting deteriorates the operation and energy efficiency of the ASHP and periodic defrosting becomes necessary. Currently the most widely used standard defrosting...
Persistent link: https://www.econbiz.de/10010702403
To investigate the impact of defrosting-water retention on the surface of heat exchangers of the air source heat pump (ASHP) performance during frosting–defrosting cycles, an experimental study has been conducted. Testing was carried out in a controlled-environment chamber with ASHP...
Persistent link: https://www.econbiz.de/10011076473
A study is presented on the characteristics of the air source heat pump (ASHP) under two kinds of typical mal-defrost phenomena. The definition of the “Mal-defrost phenomena” is put forward, and the possible origins of their occurrence are analyzed. It is concluded that the current defrost...
Persistent link: https://www.econbiz.de/10011040513
To quantify the performance drop of the air source heat pump (ASHP) system under a special kind of mal-defrost phenomenon appearing in moderate climate conditions, a field test was conducted for 8days at the initial stage of a heating season in Beijing, China. The mal-defrost was found with the...
Persistent link: https://www.econbiz.de/10011040860
When an air source heat pump (ASHP) unit is used for space heating at low ambient temperatures in winter, frost may form on its outdoor coil surface. Since the accumulated frost adversely affects its performance and energy efficiency, periodic defrosting of the outdoor coil is necessary....
Persistent link: https://www.econbiz.de/10011041471
When the surface temperature of the outdoor coil in an air source heat pump (ASHP) unit is lower than both freezing point of water and the air dew point, frost can be formed and accumulated over outdoor coil surface. Frosting affects the energy efficiency, and periodic defrosting therefore is...
Persistent link: https://www.econbiz.de/10011116053