Showing 41 - 50 of 203
Thermal response tests conducted to assess the subsurface thermal conductivity for the design of ground-coupled heat pump systems require a power source of about 7–12kW to heat water circulating in a ground heat exchanger. This high power is commonly supplied with a fuel-fired generator, which...
Persistent link: https://www.econbiz.de/10011263240
The European Energy Efficiency Building Directive 2002/91/CE, as well as other acts and funding programs, strongly promotes the adoption of passive strategies for buildings, in order to achieve indoor thermal comfort conditions above all in summer, so reducing or avoiding the use of air...
Persistent link: https://www.econbiz.de/10010805459
In this work the effect of the elbow-bend geometry and the effect of the tube arrangement on the performance of air-to-water heat exchanger is studied experimentally. In elbow-bend heat exchanger, the direction of the working fluid is bended at 90 degrees to its inlet direction. The heating or...
Persistent link: https://www.econbiz.de/10010805761
The article provides a review of solar radiation for this climatological zone, a solar house with a water flat plate collector and three storage solar heating systems, and industrial systems which was designed and constructed in order to drying ceramic and fluidization of bituminous asphalt mixing.
Persistent link: https://www.econbiz.de/10010806903
Building legislation along with environmental and comfort concerns are increasingly driving designers of building services and air conditioning equipment towards more energy efficient solutions. Heat pipe technology is emerging as a viable, efficient and environmentally-sound technology for...
Persistent link: https://www.econbiz.de/10010807249
The optimization of the heat recovery steam generator (HRSG) is one of the key elements for increasing the efficiency of combined plants. According to the current technical practice, it can be organized at different levels of complexity with objectives sequentially defined: operating parameters,...
Persistent link: https://www.econbiz.de/10010807260
Based on the entransy dissipation theory, the multi-parameter optimization design of recuperator is conducted in an Isopropanol–Acetone–Hydrogen (IAH) chemical heat pump system. The performance of the heat pump system can be improved significantly through the multi-parameter optimization,...
Persistent link: https://www.econbiz.de/10010808310
In this paper, exergy transfer effectiveness is defined to describe the performance of heat exchangers operating above/below the surrounding temperature with/without finite pressure drop. It is discussed systemically that the effects of heat transfer units number, the ratio of the heat capacity...
Persistent link: https://www.econbiz.de/10010808678
A split concept for boilers and heat recovery steam generators (HRSG), where flue gas recycling is required for controlling the maximal temperature, is proposed for reducing the heat exchange area and/or the recycling power requirements. The concept is demonstrated in the context of an HRSG of a...
Persistent link: https://www.econbiz.de/10010808775
In this research, design factors for a heat exchanger and boiler were investigated using a simplified model of a heat exchanger and pilot condensing boiler, respectively. Specifications of each heat exchanger component (e.g., upper heat exchanger (UHE) and lower heat exchanger (LHE); coil heat...
Persistent link: https://www.econbiz.de/10010809182