Availability analysis of heat recovery steam generators used in thermal power plants
The combined-cycle gas and steam turbine power plant presents three main pieces of equipment: gas turbines, steam turbines and heat recovery steam generator (HRSG). In case of HRSG failure the steam cycle is shut down, reducing the power plant output. Considering that the technology for design, construction and operation of high capacity HRSGs is quite recent its availability should be carefully evaluated in order to foresee the performance of the power plant.
Year of publication: |
2011
|
---|---|
Authors: | Carazas, F.J.G. ; Salazar, C.H. ; Souza, G.F.M. |
Published in: |
Energy. - Elsevier, ISSN 0360-5442. - Vol. 36.2011, 6, p. 3855-3870
|
Publisher: |
Elsevier |
Subject: | Availability | Reliability simulation | Heat recovery steam generator |